Code: CC51
Description: Sideways adjustment motor (M2) abnormality: Sideways adjustment motor is not rotating or puncher is not shifting normally. [MJ-1101/MJ-1106 (when MJ-6103 is installed)]
Causes: MJ-1101/MJ-1106 (When MJ-6103 is installed) Sideways adjustment motor (M2) Hole punch control PC board (HP) Sideways deviation home position sensor (S3)
Remedy: MJ-1101/MJ-1106 (When MJ-6103 is installed) Transport path If there is any paper remaining on the transport path, remove the paper. Sideways adjustment motor (M2) • If there is mechanical problem when the sideways adjustment motor (M2) is rotated, fix the mechanism. • Check the connectors and harnesses between the hole punch control PC board (HP) and sideways adjustment motor (M2). Sideways deviation home position sensor (S3) • Sensor check • Harness check
MJ-1032 Punch unit sliding motor (M12) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Punch sliding unit home position sensor (S23) abnormality Measure the voltage on TP26 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN3, CN5, CN6) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensor and connectors, exchange the hole punch control PC board (HP).
MJ-1033 Punch unit sliding motor (M16) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Punch sliding unit home position sensor (S38) abnormality Measure the voltage on pin CN5.3 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN5, CN7) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensor and connectors, exchange the hole punch control PC board (HP).
MJ-1032 Punch unit sliding motor (M12) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Punch sliding unit home position sensor (S23) abnormality Measure the voltage on TP26 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN3, CN5, CN6) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensor and connectors, exchange the hole punch control PC board (HP).
MJ-1033 Punch unit sliding motor (M16) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Punch sliding unit home position sensor (S38) abnormality Measure the voltage on pin CN5.3 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN5, CN7) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensor and connectors, exchange the hole punch control PC board (HP).