Mã lỗi ED15 — Toshiba e-Studio 306SE

Code: ED15

Description: Paddle home position error: The paddle is not at the home position. [MJ-1101/MJ-1106]
Causes: MJ-1101 Paddle motor Paddle home position sensor Finisher controller PC board
MJ-1106 Rear alignment motor Finisher controller PC board
Remedy: MJ-1101 Paddle Rotate the paddle. If there is any mechanical problem, fix its mechanism. Paddle home position sensor Paddle motor Finisher controller PC board Check if the connectors on the finisher controller PC board are disconnected from the paddle home position sensor (S3) and the paddle motor (M8), or the harnesses are open circuited. Correct if any.
MJ-1106 Rear alignment plate Move the rear alignment plate. Fix any mechanical problem. Rear alignment motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the rear alignment motor (M6) and the harnesses are open circuited. Correct if so.
MJ-1033 Transport motor-2 Paddle home position sensor The paddle home position sensor (S34) does not change from "ON" to "OFF" within the pre-specified time during paddle rotation. The paddle home position sensor (S34) does not change from "OFF" to "ON" within the pre-specified time during paddle rotation.