Code: CC21
Description: The detection of the home position of the saddle stitch 3rd transport roller drive motor ends abnormally.
Causes:
Remedy: Saddle stitch 3rd transport roller drive motor (M10) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Saddle stitch 3rd transport roller home position sensor (S23) abnormality Measure the voltage on TP67 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN6, CN16) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensor and connectors, exchange the finisher control PC board (FIN).