Code: CE00
Description: Communication error between finisher unit and puncher unit: Communication error between the finisher controller PC board and punch controller PC board.
Causes: MJ-1101 (When MJ-6103 is installed) Hole punch control PC board (HP) Finisher control PC board
Remedy: MJ-1101 (When MJ-6103 is installed) Hole punch control PC board (HP) • Check the connectors and harnesses between the hole punch control PC board (HP) and the finisher control PC board. • Board check
MJ-1033 Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN1, CN2) Abnormality of the finisher control PC board (FIN) or the hole punch control PC board (HP) If the connection of all the harnesses and connectors is normal, replace the hole punch control PC board (HP). If the error still occurs, replace the finisher control PC board (FIN).
MJ-1033 Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN1, CN2) Abnormality of the finisher control PC board (FIN) or the hole punch control PC board (HP) If the connection of all the harnesses and connectors is normal, replace the hole punch control PC board (HP). If the error still occurs, replace the finisher control PC board (FIN).