Mã lỗi CD9 — Toshiba e-Studio 3100c

Code: CD9

Description: Swing motor abnormal
Remedy: [Procedure 1] Rotate the swing motor in reverse by hand. Does the swing guide move up and down? N: Correct the swing mechanism. Y: Is the swing guide closed detection switch-2 (MS6) working normally? N: Replace the switch. Y: Is the swing guide open sensor (PI18) working normally? N: Replace the sensor. Y: Is the swing motor (M7) rotating in reverse at the specified timing? N: Replace the motor. Y: End
[Procedure 2] Is the safety zone switch (MS3) working normally? NO Replace the switch. YES Is the safety zone switch (MS3) correctly pressed? NO Correct the mechanism. YES Is the swing guide closed detection switch-2 (MS6) working normally? NO Replace the switch. YES Is the swing guide closed detection switch-2 (MS6) correctly pressed? NO Correct the mechanism. YES Replace the finisher controller PC board.
[Procedure 3] Is the swing motor clock sensor (PI20) working normally? NO Replace the sensor. YES Does the voltage between J11-6 and -7 on the finisher controller PC board become 24V when the swing motor starts rotating? NO Replace the finisher controller PC board. YES Is the wiring between the swing motor and finisher controller PC board correct? NO Correct the wiring. YES Replace the swing motor.