Code: CE4
Description: Image quality control test pattern abnormal
Remedy: (1) Use "Image quality control abnormal detection counter Y~K display/0 clearing (08- 415~418)" to check the abnormal occurring condition for each color. (2) Check "Output value display of image quality sensor/Low-density pattern (05-819)" to confirm if the value is under 300 (low-density pattern abnormal) for each color. (3) Check "Output value display of image quality sensor/High-density pattern (05-820)" to confirm if the value is 600 or above (high-density pattern abnormal) and identify the color which pattern is abnormal. (4) Set the values of "Image quality control 2(08-401)", "Image quality control 5(08-402)" and "Image quality control 4(08-411)" to "0" (disabled). (5) Output the image quality control test pattern (04-270) and check the patch of the color identified in step (3) to see if the image is abnormal (image omitted, all blank, all solid, etc.). (6) Replace the image quality sensor. (7) Set the values of "Image quality control 2 (08-401)", "Image quality control 5 (08-402)" and "Image quality control 4 (08-411)" to "1" (enabled). (8) Perform "Forced performing of image quality control (05-878)" and make sure it is completed normally (Error [CE4] does not appear). (9) Clear all "Image quality control abnormal detection counter Y~K display/0 clearing (08- 415~418)". (10)If any of the specified parts has been replaced, perform "Automatic initialization of image quality control (05-879)"