Code: CD6
Description: Saddle stitcher/microswitch abnormal
Remedy: [Procedure 1] Is the switch actuator for the inlet door working properly? N: Correct the mechanism. Y: Is the inlet cover switch (MS1S) working normally? N: Replace the switch. Y: Is the voltage of J10-8 on the saddle stitcher controller PC board 5V when the inlet door is open? Y: The inlet cover sensor (PI9S) is broken. Replace it. N: Is the voltage between J19-2 (+) and J19-1 (-) on the finisher controller PC board 24 V? N: Replace the finisher controller PC board. Y: Check and correct the wiring between J19 on the finisher controller PC board and J1 on the saddle stitcher controller PC board. If there is no problem, replace the saddle stitcher controller PC board.
[Procedure 2] Is the switch actuator for the front door working properly? N: Correct the mechanism. Y: Is the front cover switch (MS2S) working normally? N: Replace the switch. Y: Is the voltage of J11-12 on the saddle switcher controller PC board 5V when the front door is opened? Y: The front cover open/closed sensor (PI2S) is broken. Replace it. N: Replace the saddle stitcher controller PC board.
[Procedure 3] Is the switch actuator for the delivery door working properly? N: Correct the mechanism. Y: Is the delivery cover switch (MS3S) working normally? N: Replace the switch. Y: Is the voltage of J11-9 on the saddle stitcher controller PC board 5V when the delivery door is opened? Y: The delivery cover sensor (PI3S) is broken. Replace it. N: Replace the saddle stitcher controller PC board.
[Procedure 2] Is the switch actuator for the front door working properly? N: Correct the mechanism. Y: Is the front cover switch (MS2S) working normally? N: Replace the switch. Y: Is the voltage of J11-12 on the saddle switcher controller PC board 5V when the front door is opened? Y: The front cover open/closed sensor (PI2S) is broken. Replace it. N: Replace the saddle stitcher controller PC board.
[Procedure 3] Is the switch actuator for the delivery door working properly? N: Correct the mechanism. Y: Is the delivery cover switch (MS3S) working normally? N: Replace the switch. Y: Is the voltage of J11-9 on the saddle stitcher controller PC board 5V when the delivery door is opened? Y: The delivery cover sensor (PI3S) is broken. Replace it. N: Replace the saddle stitcher controller PC board.