Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E920 — Toshiba e-Studio 350

Code: E920

Description: Stop jam at the bridge unit transport sensor-1: The trailing edge of the paper does not pass the bridge unit transport sensor-1 after its leading edge has reached the sensor.
Remedy: Is there any paper remaining inside the bridge unit? YES Remove the paper. NO Are the bridge unit transport sensors-1 and -2 working? (Perform the input check:03-[FAX]ON/[3]/[H], /[3]/[E]) NO 1. Check if the connectors of the bridge unit transport sensors-1 and -2 are disconnected. 2. Check if the connector J512 of the bridge unit is disconnected. 3. Check if the connector CN302 on the LGC board is disconnected. 4. Check if the connector pins are disconnected or the harnesses are opencircuited. 5. Check if the conductor pattern on the LGC board is short- or open-circuited. 6. Replace the bridge unit transport sensors-1 and -2. 7. Replace the LGC board. YES Is the bridge unit gate solenoid working? (Perform the output check: 03-232) NO 1. Check if the connector J512 of the bridge unit is disconnected. 2. Check if the connector CN302 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are opencircuited. 4. Replace the bridge unit gate solenoid. 5. Replace the LGC board. YES Does the transport roller of the bridge unit work when the main motor is rotated? (Perform the output check: 03-101/151) NO Check the drive system of the equipment and bridge unit. YES Check if the rollers in the bridge unit are worn out.

← Xem tất cả mã lỗi Toshiba e-Studio 350

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie