Mã lỗi C130, C140 — Toshiba e-Studio 3505AC

Code: C130, C140

Description: [C130] 1st drawer tray abnormality [C140] 2nd drawer tray abnormality
Causes: Tray-up motor-1 Tray-up motor-2 PFC board LGC board 1st drawer tray-up sensor 2nd drawer tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: FS-03-242, FS-03-243) Yes 2 No • Check if the connector of the tray-up motor- 1 is disconnected (CN460, J667). • Check if the connector of the tray-up motor- 2 is disconnected (CN460, J677). • Check if the connector on the PFC board is disconnected. (CN452, CN460) • Check if the connector on the LGC board is disconnected (CN323). • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: FS-03- [ALL]OFF/[0]/[E], FS-03- [F3]ON/[4]/[E]) Yes 3 No • Check if the connector of the 1st drawer tray-up sensor is disconnected (CN457, J673, J675). • Check if the connector of the 2nd drawer tray-up sensor is disconnected (CN457, J683, J685). • Check if the connector on the PFC board is disconnected. (CN452, CN457) • Check if the connector on the LGC board is disconnected (CN323). • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 3 PFC board • Check if the conductor pattern on the PFC board is short circuited or open circuited. 4 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.

← Xem tất cả mã lỗi Toshiba e-Studio 3505AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie