Code: C473, C474

Description: [C473] Surge pressure detection / power and voltage upper limit abnormality [C474] Power and voltage lower limit abnormalityThe power voltage supplied to the IH board is higher than upper limit (C473). The power voltage supplied to the IH board is lower than upper limit (C474)
Causes: Power supply IH board LGC board
Remedy: Power supply • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Fuser unit • Drawer connector check • Thermostat check • Unit check IH board • Connector check (CN561, CN562, CN563) • Board check LGC board • Connector check (CN302, CN306) • Board check Status counter 1. Perform FS-08-2002. Change the current status counter value "13" or "16" to "0". 2. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.