Code: E110
Description: ADU misfeeding (Paper not reaching the registration sensor): The paper which has passed through ADU does not reach the registration sensor during duplex printing.
Causes: ADU motor LGC board ADU board Rollers in the ADU
Remedy: 1 Open the ADU. Is there any paper in front of the registration sensor? Yes Remove the paper. No 2 2 Is the registration sensor working? (Perform the input check in the test mode: FS-03- [ALL]OFF/[9]/[A]) Yes 3 No • Check if the connector of the 1st transport sensor is disconnected. • Check if the connector CN318 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. • Replace the 1st registration sensor. • Replace the LGC board. 3 Is the ADU clutch working? (Perform the output check in the test mode: FS-03-110/160) Yes 4 No • Check if the connector of the ADU motor is disconnected. (J691) • Check if the connector CN321 on the LGC board is disconnected. • Check if the connector CN422 and CN420 on the ADU board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. • Replace the ADU motor. • Replace the LGC board. • Replace the ADU board. 4 Rollers in the ADU • Check the rollers in the ADU. Replace them if they are worn out.