Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E520 — Toshiba e-Studio 3508A

Code: E520

Description: Stop jam in the ADU: The paper does not reach the ADU exit sensor after it has passed the ADU entrance sensor.
Causes: ADU exit sensor ADU motor LGC board ADU exit sensor ADU board Rollers in the ADU
Remedy: 1 Open the ADU. Is there any paper in front of the ADU exit sensor? Yes Remove the paper. No 2 2 Is the ADU exit sensor working? (Perform the input check in the test mode: FS-03- [ALL]OFF/[9]/[H]) Yes 3 No • Check if the connector of the ADU exit sensor is disconnected. • Check if the connector CN321 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor patterns on the LGC board or ADU board are short circuited or open circuited. • Replace the ADU exit sensor. • Replace the ADU board. • Replace the LGC board. 3 Is the ADU motor working? (Perform the output check in the test mode: FS-03-110/160) Yes 4 No • Check if the connector of the ADU motor is disconnected. • Check if the connector CN420 and CN422 on the ADU board is disconnected. • Check if the connector CN321 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor patterns on the LGC board and ADU board are short circuited or open circuited. • Replace the ADU motor. • Replace the ADU board. • Replace the LGC board. 4 ADU • Check the rollers in the ADU. Replace them if they are worn out.

← Xem tất cả mã lỗi Toshiba e-Studio 3508A

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie