Description: Paper transport jam in the Finisher (between the entrance path and sub-path sensor): The leading edge of the paper has passed the entrance sensor, but does not reach the sub-path sensor in the Finisher Unit transport path. [MJ-1042]
Causes:
Remedy: 1st transport motor (M8) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. 2nd transport motor (M4) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Entrance path sensor (S19) abnormality Measure the voltage on TP86 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V+-5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Sub-path sensor (S8) abnormality Measure the voltage on TP85 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V+-5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor.