Code: C150, C160
Description: [C150] PFP upper drawer tray is abnormal [C160] PFP lower drawer tray is abnormal
Causes: PFP board LGC board Tray-up motor Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check in the test mode: FS-03- 278, FS-03-280) Yes 2 No 1. Check if the connector of the tray-up motor is disconnected. (J967, J961, CN244) 2. Check if any of the connectors CN241 and CN244 on the PFP board is disconnected. 3. Check if the connector CN315 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check in the test mode: FS-03- [F1]ON/[5]/[A], FS-03- [F1]ON/[5]/[E]) Yes 3 No 1. Check if the connector of the sensor is disconnected. (J972, J966, J970, J965) 2. Check if any of the connectors CN241 and CN246 on the PFP board is disconnected. 3. Check if the connector CN315 on the LGC board is disconnected. 4. Check if the slit reaches the sensor. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 3 LGC board 1. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2. Replace the LGC board. 4 PFP board 1. Check if the conductor pattern on the PFP board is short circuited or open circuited. 2. Replace the PFP board.