Code: C180
Description: LCF tray-up motor is abnormal
Causes: LCF board LGC board LCF tray-up motor LCF tray-up sensor LCF feeding side bottom sensor
Remedy: 1 Does the tray move? (Perform the output check in the test mode: FS-03- 271) Yes 2 No 1. Does the tray move? (Perform the output check in the test mode: FS-03-271) 2. Check if the connector of the LCF tray-up motor is disconnected. (CN5, CN50) 3. Check if any of the connectors CN1 and CN5 on the LCF board is disconnected. 4. Check if the connector CN315 on the LGC board is disconnected. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 2 Are the LCF tray bottom sensor and LCF feeding side bottom sensor working? (Perform the input check in the test mode: FS-03- [F1]ON/[8]/[A], FS-03- [F1]ON/[8]/[E]) Yes 3 No 1. Check if the connectors of the sensors are disconnected. (CN205, CN200, CN64) 2. Check if any of the connectors CN1, CN2 and CN6 on the LCF board is disconnected. 3. Check if the connector CN315 on the LGC board is disconnected. 4. Check if the slit reaches the sensors. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 3 LGC board 1. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2. Replace the LGC board. 4 LCF board 1. Check if the conductor pattern on the LCF board is short circuited or open circuited. 2. Replace the LCF board.