Code: ED16
Description: Buffer tray home position error: The buffer tray is not at the home position. [MJ-1101/1106]
Causes: MJ-1101 Buffer tray guide motor Buffer tray home position sensor Finisher controller PC board
MJ-1106 Buffer tray home position sensor Finisher controller PC board
MJ-1106 Buffer tray home position sensor Finisher controller PC board
Remedy: MJ-1101 Buffer tray guide Open and close the buffer tray guide. If there is any mechanical problem, fix its mechanism. Buffer tray home position sensor Buffer tray guide motor Finisher controller PC board Check if the connectors on the finisher controller PC board are disconnected from the buffer tray home position sensor (S5) and the buffer tray guide motor (M3), or the harnesses are open circuited. Correct if any.
MJ-1106 Buffer tray guide Open and close the buffer tray guide. Fix any mechanical problem. Buffer tray home position sensor Check if there is a disconnection of the connector, incorrect installation or breakage of the buffer tray home position sensor (S5). If there is, reinstall the sensor correctly or replace it. Check if the connector (CN11) on the finisher controller PC board is disconnected from the buffer tray home position sensor (S5) and the harnesses are open circuited. Correct if so. Assist arm motor Check if the connector (CN13) on the finisher controller PC board is disconnected from the assist arm motor (M10) and the harnesses are open circuited. Correct if so.
MJ-1106 Buffer tray guide Open and close the buffer tray guide. Fix any mechanical problem. Buffer tray home position sensor Check if there is a disconnection of the connector, incorrect installation or breakage of the buffer tray home position sensor (S5). If there is, reinstall the sensor correctly or replace it. Check if the connector (CN11) on the finisher controller PC board is disconnected from the buffer tray home position sensor (S5) and the harnesses are open circuited. Correct if so. Assist arm motor Check if the connector (CN13) on the finisher controller PC board is disconnected from the assist arm motor (M10) and the harnesses are open circuited. Correct if so.