Mã lỗi C020 — Toshiba e-Studio 3511

Code: C020

Description: Developer motor abnormality: The developer motor is not rotating normally.
Remedy: Is the developer unit motor working? (Perform the output check: 03-112/162) NO 1. Check if the connector J578 of the developer motor is disconnected. 2. Check if the connector CN348 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are opencircuited. 4. Check if the conductor patterns on the developer motor board and LGC board are short- or open-circuited. 5. Replace the developer motor. 6. Replace the LGC board. YES 1. Check if the PLL lock signal CN348-B6 pin output from the LGC board is always level “L”. 2. Check if the voltage supplied to the ASIC input terminal IC38-150 pin is always “L”. 3. Replace the LGC board.