Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C440 — Toshiba e-Studio 3511

Code: C440

Description: Heater abnormality after abnormality judgment: The temperature of the fuser roller has exceeded the range of control (in this case, the main switch turns OFF automatically) or does not even reach the range.
Remedy: 1.2.3. Check the thermistors, IH control board, IH coil and LGC board Check the above components following the procedure 1, 2 and 3 for [C410]. 4. Clear the status counter Change the current status counter value (08-400) “4” to “0” for [C430] and “5”, “7” or “9” to “0” for [C440], taking the same procedure as that for [C410]. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred during warming-up : "4" or "5" • The error occurred after the equipment has become ready: "7" • The temperature detected by the main thermistor is 230°C or higher: "9" • The temperature detected by the sub thermistor is 230°C or higher: "9"

← Xem tất cả mã lỗi Toshiba e-Studio 3511

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie