Description: Original length sensor adjustment error: The original length sensor cannot be adjusted normally when performing the code 05-356.
Remedy: (1) Check if there are any foreign objects between the original length sensor and the reflecting mirror. Check if the reflecting mirror is dirty. (2) Check if the harness connecting the original length sensor and the RADF board is open-circuited. (3) Check if the conductor pattern on the RADF board is short- or open-circuited. (4) Replace the original length sensor. (5) Replace the RADF board.