Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CE40 — Toshiba e-Studio 3511

Code: CE40

Description: Image quality control test pattern abnormality: The test pattern is not formed normally
Remedy: (1) Use "Image quality control abnormal detection counter Y to K display/0 clearing (08-573 to 576)" to check the abnormal occurring condition for each color. (2) Check “Output value display of image quality sensor / Low-density pattern (05-391-0 to 3)” to check if the low-density pattern abnormality occurs for each color. The values under 320 for Y, M and C, and under 270 for K are defined as low-density pattern abnormality. Under 320 (Y, M and C) Under 270 (K) Low-density pattern abnormality Check the transfer belt. If the cleaning is poor, correct the transfer belt around its cleaning blade. 320 or above (Y, M and C) 270 or above (K) To (9) (3) Check “Output value display of image quality sensor / High-density pattern (05-390-0 to 3)” to check if the high-density pattern abnormality occurs for each color and identify the color which pattern is abnormal. If the value is 630 or above, it is defined as high-density pattern abnormality. (4) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Image quality closed-loop control / Laser power (08-557)” to “0” (Invalid). (5) Perform “Enforced performing of image quality open-loop control (05-394)”. (6) Output the image quality control test pattern (04-270) more than one time and check the patch of the color identified in step (3) to see if the image is abnormal (Note). Abnormal Correct the items related to the image. Normal To (9) (7) Replace the image quality sensor. (8) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Image quality closed-loop control / Laser power (08-557)” to “1” (Valid). (9) Perform “Enforced performing of image quality open-loop control (05-394)” and make sure it is completed normally. (Error [CE40] does not appear.) Then perform “Automatic gamma adjustment “. (10) Clear all "Image quality control abnormal detection counter Y to K display/0 clearing (08-573 to 576)". Note Abnormal image: Blank print, Solid print, White banding, Color banding, White spots, Poor transfer, Uneven image density, Faded image (low density), Uneven light distribution, Blotched image

← Xem tất cả mã lỗi Toshiba e-Studio 3511

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie