Code: CEB0
Description: Black developer unit lifting movement abnormality: The black developer unit does not move up or down normally (lifting cam does not operate normally).
Remedy: Is the black developer lifting clutch working properly? (Perform the output check: 03-433) NO 1. Check if the connector of the black developer lifting clutch is disconnected. 2. Check if the connector CN362 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the wires of harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the black developer lifting clutch. 6. Replace the LGC board. YES Are the black developer contact position detection sensor and black developer contact timing detection sensor working properly? (Perform the input check: 03-[FAX]ON/[1]/[C], /[1]/[B] NO 1. Check if the connectors of the black developer contact position detection sensor or black developer contact timing detection sensor are disconnected. 2. Check if the connector CN361 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the wires of harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the black developer contact position detection sensor and black developer contact timing detection sensor. 6. Replace the LGC board. YES 1. Check if the conductor pattern on the LGC board is short- or open-circuited. 2. Replace the LGC board.