Description: Revolver motor abnormality: Revolver motor is not rotating or revolver is not moving normally.
Remedy: Is the revolver motor working? (Perform the output check: 03-450) NO 1. Check if the connector of the revolver motor is disconnected. 2. Check if the connectors CN435 and J434 on the DRV board are disconnected. 3. Check if the connector CN360 on the LGC board is disconnected. 4. Check if the connector pins are disconnected or the harnesses are open-circuited. 5. Check if the conductor patterns on the DRV board and LGC board are short- or open-circuited. 6. Replace the revolver motor. 7. Replace the DRV board and LGC board. YES 1. Check if the conductor patterns on the DRV board and LGC board are short- or open-circuited. 2. Replace the DRV board and LGC board.