Code: C446
Description: Heater lamp abnormality after abnormality judgment (pre-running end temperature abnormality)
Remedy: 1,2.3. Check the thermistors, Heater and LGC board Check the above components following the procedures 1, 2 and 3 for [C411/C412]. 4. Clear the status counter Change the current status counter value (08-400) "3", "5" , "6" , "9" , "19" , "21" , "22" , "23" , "24" , "25" , "27" or "29" to "0" for [C44X], taking the same procedure as that for [C41X]. • The status counter value is as follows in the following cases. - The error occurred during warming-up: "3", "5" or "6" - The error occurred after the equipment has become ready: "7" - The temperature detected by the center thermistor is 240°C or higher, the temperature detected by the side thermistor is 250°C or higher or the temperature detected by the edge thermistor is 270°C or higher: "9", "19", "21", "22", "23", "25", "27" or "29". - The error occurred during printing: "24" or "25" - The error occurred during energy saving: "26" or "27" - A paper jam occurred: "28" or "29"