Code: C480
Description: Overheating of IGBT: The temperature of the IGBT rises abnormally.
Remedy: 1. Check the operation of the IH control board cooling fan Check if the IH control board cooling fan is rotating normally. (Is the connector securely connected?) 2. Check the IH board (1) Check if the IGBT or IGBT radiation plate is normal. (Is the radiation plate securely attached?) (2) Check if the conductor pattern on the board is short circuited or open circuited. (3) Replace the IH board. 3. Clear the status counter Change the values “12”, “15” or “18” of the status counter (08-400) to “0”. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred before the temperature of the fuser roller reaches 40°C: "12" • The error occurred before the equipment has become ready: "15" • The error occurred when the equipment is in the ready state: "18" (When the only one side of IH coil is energized continuously for 15 seconds)