Code: CA10
Description: Polygonal motor abnormality: The polygonal motor is not rotating normally.
Remedy: Is the polygonal motor rotating? ↓→ NO → 1) Check if the connector CN342 on the LGC board is disconnected. 2) Check if the harness is open circuited or the connector pin is disconnected. 3) Check if the conductor pattern on the LGC board is short circuited or open circuited. 4) Replace the laser optical unit. 5) Replace the LGC board. YES Is the printed image distorted? ↓→ YES → 1) Check if the connector CN342 on the LGC board is almost disconnected. 2) Check if the harness is almost open circuited or the connector pin is almost disconnected. 3) Check if the conductor pattern on the LGC board is short circuited or open circuited. 4) Check if the laser unit cooling fan is stopped. 5) Check if the suction area of laser unit cooling fan is plugged up. 6) Replace the laser optical unit. 7) Replace the LGC board. NO 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Check if the units with high-voltage (developer unit, transfer belt unit and 2nd transfer roller unit) are securely grounded. 3) Check if the bias supply joints of the units with high-voltage are securely connected or they are not stained. 4) Check if the plate in paper transport system is securely grounded. 5) Check if the equipment is grounded. 6) Check if the laser unit cooling fan is stopped. 7) Check if the suction area of laser unit cooling fan is plugged up. 8) Replace the laser optical unit. 9) Replace the LGC board.