Description: RADF open jam: RADF has opened during RADF operation
Remedy: Is the RADF opened? → YES → Remove the original, if any, and close the RADF. NO Is the RADF opening/closing sensor adjusted within the specified range? → NO → Adjust the RADF opening/closing sensor. YES Is the RADF opening/closing sensor working? (Perform the input check: 03-[FAX]ON/[7]/[D]) ↓→ NO → 1) Check if the connector of the RADF opening/closing sensor is disconnected. 2) Check if the connector CN75 on the RADF board is disconnected. 3) Check if the connector pins are disconnected or the harnesses are open circuited. 4) Check if the conductor pattern on the RADF board is short circuited or open circuited. 5) Replace the RADF opening/closing sensor. 6) Replace the RADF board. YES Replace the RADF board.