Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E110 — Toshiba e-Studio 352

Code: E110

Description: ADU misfeeding (Paper not reaching the 1st transport sensor): The paper which has passed through ADU does not reach the 1st transport sensor during duplex printing.
Remedy: Open the jam access cover. Is there any paper in front of the registration sensor? YES Remove the paper. NO Is the registration sensor working? (Perform the input check in the test mode:03-[FAX]ON/[2]/[A]) NO 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN318 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES Is the ADU clutch working? (Perform the output check in the test mode: 03-222) NO 1. Check if the connector of the ADU clutch is disconnected. 2. Check if the connector CN304 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the ADU clutch. 6. Replace the LGC board. YES Check the rollers in the ADU. Replace them if they are worn out.

← Xem tất cả mã lỗi Toshiba e-Studio 352