Description: Jam not reaching the ADU entrance sensor: The paper does not reach the ADU entrance sensor after it is switchbacked in the exit section.
Remedy: Open the ADU. Is there any paper in front of the ADU exit sensor? YES Remove the paper. NO Is the ADU exit sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[G]) NO 1. Check if the connector of the ADU exit sensor is disconnected. 2. Check if either of the connectors CN211 or CN213 on the ADU board is disconnected. 3. Check if the connector CN304 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are opencircuited. 5. Check if the conductor patterns on the ADU board and LGC board are shortor open-circuited. 6. Replace the ADU exit sensor. 7. Replace the ADU board. 8. Replace the LGC board. YES Is the ADU clutch working? (Perform the output check in the test mode: 03-222) NO 1. Check if the connector of the ADU clutch is disconnected. 2. Check if the connector CN304 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the ADU clutch. 6. Replace the LGC board. YES Check the rollers in the ADU. Replace them if they are worn out.