Mã lỗi C440 — Toshiba e-Studio 353

Code: C440

Description: Heater abnormality after abnormality judgment: The temperature of the fuser roller has exceeded the range of control (in this case, the main switch turns OFF automatically) or does not even reach the range.
Remedy: 1,2.3. Check the thermistors, IH board, IH coil and LGC board Check the above components following the procedures 1, 2 and 3 for [C410]. 4. Clear the status counter Change the current status counter value (08-400) “5”, “7” or “9” to “0” for [C440], taking the same procedure as that for [C410]. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred during warming-up: "5" • The error occurred after the equipment has become ready: "7" • The temperature detected by the main thermistor is 230°C or higher: "9" • The temperature detected by the edge thermistor is 280°C or higher: "9"