Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C470 — Toshiba e-Studio 353

Code: C470

Description: IH initialization or IH power voltage abnormality: The AC input is not applied to the IH control circuit normally, or the input voltage is too high/low.
Remedy: 1. Check the AC input voltage Check if the AC input voltage is within the specified range. (especially when the heater becomes ON after the power is turned ON (the equipment is warming up)) 2. Check the thermostat Check if the thermostat is blown. 3. Check the IH board (1) Check if the AC input connector on the IH board or the LGC I/F connector CN455/456 is disconnected? (2) Check if the fuse on the IH board has blown. (3) Replace the IH board. 4. Check the LGC board (1) Check if the connector CN316 is disconnected. (2) Check if the conductor pattern on the board is short- or open-circuited. (3) Replace the LGC board. 5. Clear the status counter Change the values “10”, “11”, “14” or “17” of the status counter (08-400) to “0”. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred immediately after the power was turned ON: "10" • The error occurred before the temperature of the fuser roller reaches 40°C: "11" • The error occurred before the equipment has become ready: "14" • The error occurred when the equipment is in the ready state or during printing: "17"

← Xem tất cả mã lỗi Toshiba e-Studio 353