Code: E510
Description: Stop jam in the ADU: The paper does not reach the ADU exit sensor after it has passed the ADU entrance sensor.
Remedy: Open the ADU. Is there any paper in front of the ADU entrance sensor? YES Remove the paper. NO Is the ADU entrance sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[H]) NO 1. Check if the connector of the ADU entrance sensor is disconnected. 2. Check if either of the connectors CN211 or CN214 on the ADU board is disconnected. 3. Check if the connector CN304 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are opencircuited. 5. Check if the conductor patterns on the ADU board and LGC board are shortor open-circuited. 6. Replace the ADU entrance sensor. 7. Replace the ADU board. 8. Replace the LGC board. YES Is the exit motor (rotating in reverse) working? (Perform the output check in the test mode: 03-121/171) NO 1. Check if the connector of the exit motor is disconnected. 2. Check if the connector CN3 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the exit motor. 6. Replace the LGC board. YES Is the ADU motor working? (Perform the output check in the test mode: 03-110/160) NO 1. Check if the connector of the ADU motor is disconnected. 2. Check if any of the connectors CN211, CN212 and CN215 on the ADU board is disconnected. 3. Check if the connector CN304 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are opencircuited. 5. Check if the conductor patterns on the ADU board and LGC board are shortor open-circuited. 6. Replace the ADU motor. 7. Replace the ADU board. 8. Replace the LGC board. YES Check the rollers in the ADU and the exit roller of the equipment. Replace them if they are worn out.