Code: EB50
Description: Paper remaining on the transport path: The multiple feeding of preceding paper caused the misfeeding of upcoming paper.
Remedy: In case the paper is fed from the upper drawer, bypass unit or ADU: Open the jam access cover. Is there any paper in front of the registration sensor? YES Remove the paper. NO When the paper is fed from the upper drawer: Is the upper drawer feed sensor working? (Perform the input check: 03-[FAX]ON/[6]/[E]) NO 1. Check if the connector of the upper drawer feed sensor is disconnected. 2. Check if the connector CN318 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the upper drawer feed sensor. 6. Replace the LGC board. YES When the paper is fed from the bypass feed unit: Is the bypass feed sensor working? (Perform the input check: 03-[FAX]ON/[4]/[F]) NO 1. Check if the connector of the bypass feed sensor is disconnected. 2. Check if the connector CN304 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the bypass feed sensor. 6. Replace the LGC board. YES YES When the paper is fed from the ADU: Is the ADU exit sensor working? (Perform the input check: 03-[FAX]OFF/[1]/[G]) NO 1. Check if the connector of the ADU exit sensor is disconnected. 2. Check if either of the connectors CN211 or CN213 on the ADU board is disconnected. 3. Check if the connector CN304 on the LGC board is disconnected. 4. Check if the connector pins are disconnected or the harnesses are opencircuited. 5. Check if the conductor patterns on the ADU board and LGC board are shortor open- circuited. 6. Replace the ADU exit sensor. 7. Replace the ADU board. 8. Replace the LGC board. YES Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[2]/[A]) NO 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector CN318 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES Check the rollers. Replace them if they are worn out.
In case the paper is fed from the lower drawer, PFP or LCF: Open the jam access cover. Is there any paper in front of the upper drawer feed sensor? YES Remove the paper. NO Are the upper/lower drawer feed sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[6]/[E], /[7]/[E]) NO 1. Check if the connector of the upper/lower drawer feed sensor is disconnected. 2. Check if the connector CN318 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the upper/lower drawer feed sensor. 6. Replace the LGC board. YES Check the rollers. Replace them if they are worn out.
In case the paper is fed from the lower drawer, PFP or LCF: Open the jam access cover. Is there any paper in front of the upper drawer feed sensor? YES Remove the paper. NO Are the upper/lower drawer feed sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[6]/[E], /[7]/[E]) NO 1. Check if the connector of the upper/lower drawer feed sensor is disconnected. 2. Check if the connector CN318 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the upper/lower drawer feed sensor. 6. Replace the LGC board. YES Check the rollers. Replace them if they are worn out.