Code: EA70
Description: Stack exit belt home position error: The stack exit belt is not at the home position. [MJ-1101/ 1106] Stack slider home position error: The stack slider is not at the home position. [MJ-1031]
Causes: MJ-1101 Stack belt exit home position sensor Stack transport motor Finisher controller PC board
MJ-1031 Stack slider HP sensor Stack slide motor Finisher controller PC board
MJ-1106 Stack belt exit home position sensor Stack transport motor Finisher controller PC board
MJ-1031 Stack slider HP sensor Stack slide motor Finisher controller PC board
MJ-1106 Stack belt exit home position sensor Stack transport motor Finisher controller PC board
Remedy: MJ-1101 Stack belt exit home position sensor Check if the connector CN11 on the finisher controller PC board is disconnected from the stack belt exit home position sensor (S9) and the harnesses are open circuited. Correct if any. Stack transport motor Is the harness between the stack transport motor (M5) and the finisher control PC board (CN10) disconnected or open circuited?
MJ-1031 Stack slider HP sensor Check if the connector J111 on the finisher controller PC board is disconnected from the stack edging HP sensor (SR8) or the harnesses are open circuited. Correct if any. Stack slide motor Check if the connector J111 on the finisher controller PC board is disconnected from the stack slide motor (M4) or the harnesses are open circuited. Correct if any.
MJ-1106 Stack belt exit home position sensor Check if there is a disconnection of the connector, incorrect installation or breakage of the stack belt exit home position sensor (S9). If there is, reinstall the sensor correctly or replace it. Check if the connector (CN18) on the finisher controller PC board is disconnected from the stack belt exit home position sensor (S9) and the harnesses are open circuited. Correct if any. Stack transport motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the stack transport motor (M8) and the harnesses are open circuited. Correct if any.
MJ-1031 Stack slider HP sensor Check if the connector J111 on the finisher controller PC board is disconnected from the stack edging HP sensor (SR8) or the harnesses are open circuited. Correct if any. Stack slide motor Check if the connector J111 on the finisher controller PC board is disconnected from the stack slide motor (M4) or the harnesses are open circuited. Correct if any.
MJ-1106 Stack belt exit home position sensor Check if there is a disconnection of the connector, incorrect installation or breakage of the stack belt exit home position sensor (S9). If there is, reinstall the sensor correctly or replace it. Check if the connector (CN18) on the finisher controller PC board is disconnected from the stack belt exit home position sensor (S9) and the harnesses are open circuited. Correct if any. Stack transport motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the stack transport motor (M8) and the harnesses are open circuited. Correct if any.