Code: E000-0000
Description: Fixing unit startup defect
The detected temperature of the main thermistor does not rise after the heater is energised.
The detected temperature of the main thermistor does not rise after the heater is energised.
Causes: Main thermistor broken wire, fixer heater broken wire, DC controller PCB defect.
Remedy: • Check the connector of the fixing unit, DC controller PCB, fixing power supply unit. • Replace the fixing film unit. • Replace the fixing power supply unit. • Replace the DC controller PCB.