Code: C1A0
Description: LCF end fence motor abnormality: The LCF end fence motor is not rotating or the LCF end fence is not moving normally.
Remedy: Is the LCF end fence motor working? (Perform the output check in the test mode: 03-207) NO 1. Check if the connector of the LCF end fence motor is disconnected. 2. Check if any of the connectors CN1 and CN5 on the LCF board is disconnected. 3. Check if the connector CN318 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 6. Replace the LCF board. 7. Replace the LGC board. YES Are the LCF end fence home/stop position sensors working? (Perform the input check in the test mode: 03-[FAX]OFF/[5]/[D], /[5]/[C]) NO 1. Check if the connectors of the sensors are disconnected. 2. Check if either of the connectors CN1 or CN4 on the LCF board is disconnected. 3. Check if the connector CN318 on the LGC board is disconnected. 4. Check if the slit reaches the sensors. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 7. Replace the LCF board. 8. Replace the LGC board. YES 1. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2. Replace the LGC board.