Code: CC30
Description: Paddle motor abnormality: The paddle motor is not rotating normally or the swing guide is not moving normally. [MJ-1025] Stack transport motor abnormality: The stack transport motor is not rotating or the stack transport belt is not moving normally. [MJ-1101] Stack delivery motor abnormality: The stack delivery motor is not rotating normally. [MJ-1031]
Remedy: MJ-1025 Is the paddle home position sensor (PI2) working properly? NO Replace the sensor. YES Is the swing guide home position sensor (PI3) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and paddle motor (M2) correct? NO Correct the wiring. YES Try turning the paddle motor counterclockwise by hand. Is there mechanical trapping in the up/down movement of the swing guide? YES Fix the mechanism. NO Try replacing the paddle motor. Is the problem corrected? YES End. NO Replace the finisher controller PC board.
MJ-1031 1. Check if the connector J111 on the finisher controller PC board is disconnected from the stack edging HP sensor (SR8) or the harnesses are open circuited. Correct if any. 2. Check if the connector J111 on the finisher controller PC board is disconnected from the stack slide motor (M4) or the harnesses are open circuited. Correct if any. 3. Replace the stack edging HP sensor. 4. Replace the stack slide motor. 5. Replace the finisher control PC board.
MJ-1101 Is there any mechanical problem when the stack transport belt is moved? ..YES Fix the mechanism. NO Is the harness between the stack transport motor (M5) and the finisher control PC board (CN10) disconnected or open circuited? l ..YES • Reconnect the connector securely. • Replace the harness. NO 1. Replace the stack transport motor (M5). 2. Replace the finisher control PC board.
MJ-1031 1. Check if the connector J111 on the finisher controller PC board is disconnected from the stack edging HP sensor (SR8) or the harnesses are open circuited. Correct if any. 2. Check if the connector J111 on the finisher controller PC board is disconnected from the stack slide motor (M4) or the harnesses are open circuited. Correct if any. 3. Replace the stack edging HP sensor. 4. Replace the stack slide motor. 5. Replace the finisher control PC board.
MJ-1101 Is there any mechanical problem when the stack transport belt is moved? ..YES Fix the mechanism. NO Is the harness between the stack transport motor (M5) and the finisher control PC board (CN10) disconnected or open circuited? l ..YES • Reconnect the connector securely. • Replace the harness. NO 1. Replace the stack transport motor (M5). 2. Replace the finisher control PC board.