Description: Drum thermistor abnormality: The output value of the drum thermistor-K is out of a specified range.
Remedy: MJ-1025 (when MJ-6005 is installed) Is the problem solved by turning the power of the equipment OFF and ON? YES End. NO Is the wiring between the finisher controller PC board and the punch controller PC board correct? NO Correct the wiring. YES Measure the voltage between CN14-5 (+) and CN14-3 (-) on the finisher controller PC board 24 V? NO Replace the finisher controller PC board. YES Replace the punch controller PC board.
MJ-1024 (When MJ-6004 is installed) Is the problem solved by turning OFF and ON the power of the equipment? YES.. End. NO Is the wiring between the finisher controller PC board and punch controller PC board correct? NO Correct the wiring. YES 1. Replace the finisher controller PC board. 2. Replace the punch controller PC board.
MJ-1101 (When MJ-6101 is installed) Is the harness between the hole punch control PC board (HP) and the finisher control PC board disconnected or open circuited? ..YES Replace the harness. Correct the wiring. NO Is the conductor pattern on the hole punch control PC board (HP) open circuited or short circuited? ..YES Replace the hole punch control PC board (HP). NO Replace the finisher control PC board.