Mã lỗi E950 — Toshiba e-Studio 355

Code: E950

Description: Jam not reaching the job separator transport sensor: The paper has passed through the exit sensor does not reach the job separator transport sensor.
Remedy: Open the JSP cover. Is there any paper on the transport path? YES Remove the paper. NO Is the JSP feed sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[3]/[D]) NO 1. Check if the connector of the JSP feed sensor is disconnected. 2. Check if either of the connectors CN260 or CN262 on the JSP board is disconnected. 3. Check if the connector CN302 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the JSP board and LGC board are short circuited or open circuited. 6. Replace the JSP feed sensor. 7. Replace the JSP board. 8. Replace the LGC board. YES 1. Replace the JSP board. 2. Replace the LGC board.