Code: CC60
Description: Punch motor abnormality [MJ-1036]
Causes:
Remedy: MJ-1036 Punch motor (M11) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Rear punch shaft home position sensor (S22) abnormality Measure the voltage on TP25 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch shaft home position sensor (S26) abnormality Measure the voltage on TP24 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch motor clock sensor (S20) abnormality Measure the voltage on TP27 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN2, CN5, CN6) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the hole punch control PC board (HP).