Mã lỗi CC60 — Toshiba e-Studio 356

Code: CC60

Description: Punch motor abnormality: Punch motor is not rotating or puncher is not shifting normally.]
Causes:
Remedy: MJ-1032 Punch motor (M11) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Rear punch shaft home position sensor (S22) abnormality Measure the voltage on TP25 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch shaft home position sensor (S26) abnormality Measure the voltage on TP24 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch motor clock sensor (S20) abnormality Measure the voltage on TP27 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN2, CN5, CN6) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the hole punch control PC board (HP).
MJ-1033 Punch motor (M15) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Punch shaft home position sensor (S36) abnormality Measure the voltage on pin CN3.3 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch shaft rotational direction sensor (S35) abnormality Measure the voltage on pin CN3.9 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch motor clock sensor (S37) abnormality Measure the voltage on pin CN3.6 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN3, CN6) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the hole punch control PC board (HP).

← Xem tất cả mã lỗi Toshiba e-Studio 356

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie