Mã lỗi CB50 — Toshiba e-Studio 356S

Code: CB50

Description: Stapler home position error: The stapler home position sensor does not work. [MJ-1101/MJ-1106] Stapler unit home position detection error: The detection of the home position of the stapler unit ends abnormally. [MJ-1032/MJ-1033]
Causes: MJ-1101 Finisher controller PC board
MJ-1106 Stapler Finisher controller PC board
Remedy: MJ-1101 Stapler • Check the connectors and harnesses between the stapler(M4) and finisher controller PC board (CN2). • Check the harnesses in the stapler.
MJ-1106 Stapler • Check the connectors and harnesses between the stapler and finisher controller PC board (CN19). • Check the harnesses in the stapler.
MJ-1032 Staple motor (M10) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the staple unit. Staple unit clinching home position sensor (S16) abnormality Measure the voltage on CN16 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when the sensor is ON and within the range of 3.3V ± 5% when OFF. If the voltage does not fall within the range mentioned, replace the staple unit. Staple unit improper clinching prevention sensor (S15) abnormality Measure the voltage on TP25 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN16, CN17) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors, switch and connectors, exchange the finisher control PC board (FIN).
MJ-1033 Edge staple unit motor (M13) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the staple unit. Edge staple unit clinching home position sensor (S29) abnormality Measure the voltage on pin CN10.4 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when the sensor is ON and within the range of 5V ± 5% when OFF. If the voltage does not fall within the range mentioned, replace the staple unit. Edge staple unit improper clinching prevention sensor (S25) abnormality Measure the voltage on pin CN10.11 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Edge staple unit interference switch (SW3) abnormality Measure the voltage on pin CN18.8 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when the switch is ON and within the range of 24V ± 10% when OFF. If the voltage does not fall within the range mentioned, replace the switch. (Be sure that all covers and doors are closed before starting measurement.) Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN10, CN18, CN24) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors, switch and connectors, exchange the finisher control PC board (FIN).