Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CDF0 — Toshiba e-Studio 356S

Code: CDF0

Description: Initialization error of the offset tray: The home position of the separator cannot be detected when the power is turned ON.
Causes: OCT motor OCT board LGC board
(e-STUDIO356/456/506) Offset gate motor. MOT2 board LGC board
Remedy: OCT motor OCT board LGC board 1. Check if each connector between the OCT motor and OCT board (CN261) is disconnected. 2. Check if each connector between the OCT board (CN261) and LGC board (CN302) is disconnected. 3. Check if each connector pin is removed or the harness is broken. 4. Check if any conductor pattern on the OCT board and LGC board is short circuited or open circuited.
(e-STUDIO356/456/506) Offset gate motor MOT2 board LGC board 1. Check if each connector between the offset gate motor and MOT2 board (CN406) is disconnected. 2. Check if each connector between the MOT2 board (CN406) and LGC board (CN302) is disconnected. 3. Check if each connector pin is removed or the harness is broken. 4. Check if any conductor pattern on the MOT2 board and LGC board is short circuited or open circuited.