Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi ED13 — Toshiba e-Studio 356SD

Code: ED13

Description: Front alignment plate home position error: The front alignment plate is not at the home position. [MJ- 1101/MJ-1106]
Causes: MJ-1101 Front alignment motor Front alignment plate home position sensor Finisher controller PC board
MJ-1106 Front alignment plate home position sensor Finisher controller PC board
Remedy: MJ-1101 Front alignment plate Move the front alignment plate. If there is any mechanical problem, fix its mechanism. Front alignment motor Front alignment plate home position sensor Finisher controller PC board Check if the connectors on the finisher controller PC board are disconnected from the front alignment plate home position sensor (S7) and the front alignment motor (M9), or the harnesses are open circuited. Correct if any.
MJ-1106 Front alignment plate Move the front alignment plate. Fix any mechanical problem. Front alignment plate home position sensor Check if there is a disconnection of the connector, incorrect installation or breakage of the front alignment plate home position sensor (S7). If there is, reinstall the sensor correctly or replace it. Check if the connector (CN18) on the finisher controller PC board is disconnected from the front alignment plate home position sensor (S7) and the harnesses are open circuited. Correct if so. Front alignment motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the front alignment motor (M5) and the harnesses are open circuited. Correct if so.

← Xem tất cả mã lỗi Toshiba e-Studio 356SD

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie