Code: CC22
Description: The detection of the home position of the saddle stitch stapler unit ends abnormally.
Causes:
Remedy: Saddle stitch stapler motor (M14) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the saddle stitch staple unit. Saddle stitch staple unit clinching home position sensor (S32) abnormality Measure the voltage on pin CN17.5 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when the sensor is ON and within the range of 5V±5% when OFF. If the voltage does not fall within the range mentioned, replace the saddle stitch staple unit. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the saddle stitch staple unit. Finisher control PC board (FIN) abnormality If the error still occurs after replacing the saddle stitch staple unit and the connectors, exchange the finisher control PC board (FIN). Saddle stitch staple empty sensor (S33) abnormality Measure the voltage on pin CN17.7 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when the sensor is ON and within the range of 5V±5% when OFF. If the voltage does not fall within the range mentioned, replace the saddle stitch staple unit. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the saddle stitch staple unit. Finisher control PC board (FIN) abnormality If the error still occurs after replacing the saddle stitch staple unit and the connector, exchange the finisher control PC board (FIN).