Description: Lower drawer tray abnormality: The lower drawer tray motor is not rotating or the lower drawer tray is not moving normally.
Causes: LGC board Tray-up motor Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check in the test mode: 03-242/ 243) Yes 2 No 1. Check if the connector of the tray-up motor is disconnected. 2. Check if the connector CN316 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the LGC board. 2 Is the tray-up sensor working? (Perform the input check in the test mode: 03- [FAX]OFF/[6]/[B], /[7]/[B]) Yes 3 No 1. Check if the connector of the sensor is disconnected. 2. Check if the connector CN315 on the LGC board is disconnected. 3. Check if the slit reaches the sensor. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 6. Replace the LGC board. 3 LGC board 1. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2. Replace the LGC board.