Description: Stop jam at the bridge unit transport sensor-2: The trailing edge of the paper does not reach the bridge unit transport sensor-2 after its leading edge has reached the bridge unit transport sensor-2.
Causes: Bridge unit transport sensor-2 LGC board
Remedy: 1 Bridge unit Check if there is any paper in the bridge unit and remove it if there is. 2 2 Is the bridge unit transport sensor-2 working? (Perform the input check : 03-[FAX]OFF/[3]/[G]) / 03- [FAX]OFF/[4]/[G]) Yes 3 No 1. Check if the connector CN334 on the LGC board is disconnected from the bridge unit transport sensor-2 (exit sensor) or the harnesses are open circuited. Check if the connector J523 of the bridge unit is disconnected. Correct if any. 2. Replace the bridge unit transport sensor-2. 3. Replace the LGC board. 3 Does the transport roller of the bridge unit work when the fuser motor is rotated? (Perform the output check: 03-113/163) Yes Check if the rollers in the exit roller, the pressure spring and the bridge unit are worn out. No Check the drive system of the equipment and bridge unit.