Code: F101_2

Description: Normal partition mount error (HDD normal partition mounting fails.): The HDD cannot be connected (mounted) caused by damage to areas other than those described in the F101_0 and F101_1 errors.
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. 2. If the error still occurs after step 1, perform the following. - Perform [3C] → [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error persists after step 2, perform the following. - Check if the state of each partition is "OK" by performing [5]+[C]+[POWER] → 6. DISK Info. - If the state of partition is "NG", initialize the partition by performing [5]+[C]+[POWER] → 3. Initialize HDD. Notes: The following items will be deleted by performing step 3. . Message Log . Job Log . Spool Data (Print, Email reception) . Template 4. If the error still persists after step 3, perform the following. - Perform [3C] → [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. 5. If the error persists even after step 4, replace the HDD.