Mã lỗi C180 — Toshiba e-Studio 450

Code: C180

Description: LCF tray-up motor abnormality: The LCF tray-up motor is not rotating or the LCF tray is not moving normally.
Remedy: Does the tray move? (Perform the output check in the test mode: 03-271) NO 1. Check if the connector of the LCF tray-up motor is disconnected. 2 Check if any of the connectors CN100, CN101 and CN103 on the LCF board is disconnected. 3. Check if the connector CN303 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are opencircuited. 5. Check if the conductor patterns on the LCF board and LGC board are shortor open-circuited. 6. Replace the LCF board. 7. Replace the LGC board. YES Are the LCF tray bottom sensor and LCF tray-up sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[5]/[F], /[3]/[A] NO 1. Check if the connectors of the sensors are disconnected. 2. Check if any of the connectors CN100, CN104 and CN105 on the LCF board is disconnected. 3. Check if the connector CN303 on the LGC board is disconnected. 4. Check if the slit reaches the sensors. 5. Check if the connector pins are disconnected and the harnesses are opencircuited. 6. Check if the conductor patterns on the LCF board and LGC board are shortor open-circuited. 7. Replace the LCF board. 8. Replace the LGC board. YES 1. Check if the conductor pattern on the LGC board is short- or open-circuited. 2. Replace the LGC board.

← Xem tất cả mã lỗi Toshiba e-Studio 450

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie