Mã lỗi SC543 — Toshiba e-Studio 4500c
Code:
SC543
Description: Heating roller thermistor 1 error 3: Software - High temperature. The thermistor detected a temperature over 230°C.
Remedy: • TRIAC short • IOB defective • BICU defective • Fusing temperature out of control Do SP5810 to cancel the SC fusing code.