Code: C130, C140
Description: [C130] 1st drawer tray abnormality [C140] 2nd drawer tray abnormality
Causes: Tray-up motor-1 Tray-up motor-2 PFC board LGC board 1st drawer tray-up sensor 2nd drawer tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: FS-03-242, FS-03-243) Yes 2 No • Check if the connector of the tray-up motor- 1 is disconnected (CN460, J667). • Check if the connector of the tray-up motor- 2 is disconnected (CN460, J677). • Check if the connector on the PFC board is disconnected. (CN452, CN460) • Check if the connector on the LGC board is disconnected (CN323). • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: FS-03- [ALL]OFF/[0]/[E], FS-03- [F3]ON/[4]/[E]) Yes 3 No • Check if the connector of the 1st drawer tray-up sensor is disconnected (CN457, J673, J675). • Check if the connector of the 2nd drawer tray-up sensor is disconnected (CN457, J683, J685). • Check if the connector on the PFC board is disconnected. (CN452, CN457) • Check if the connector on the LGC board is disconnected (CN323). • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 3 PFC board • Check if the conductor pattern on the PFC board is short circuited or open circuited. 4 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.